JEHCCU0040CM1 |
JEHCCU0063CM1 |
JEHCCU0095CM1 |
JEHCCU0100CM1 |
JEHCCU0113CM1 |
JEHCCU0140CM1 |
JEHCCU0170CM1 |
JEHCCU0050CM1 |
JEHCCU0051CM1 |
JEHCCU0067CM1 |
JEHCCU0077CM1 |
JEHCCU0150CM1 (Archivé) |
JEHCCU0225CM1 (Archivé) |
JEHCCU0300CM1 (Archivé) |
Puissance frigorifique |
Temp. moyenne |
R-134a |
Nom. |
kW |
0.59 |
1.06 |
1.60 |
|
|
|
|
|
0.89 |
|
1.28 |
1.27 (1) |
2.06 (1) |
2.99 (1) |
|
|
R-404A |
Nom. |
kW |
|
|
|
|
|
|
|
|
|
|
|
2.27 (1) |
3.76 (1) |
4.81 (1) |
|
|
R-407A |
Nom. |
kW |
|
|
|
1.33 |
1.66 |
1.92 |
|
0.80 |
|
1.07 |
|
2.04 (1) |
3.37 (1) |
4.30 (1) |
|
|
R-407F |
Nom. |
kW |
|
|
|
1.41 |
1.74 |
2.08 |
|
0.86 |
|
1.15 |
|
1.99 (1) |
3.40 (1) |
4.55 (1) |
Puissance absorbée |
Moyennes températures |
R-134a |
Nom. |
kW |
0.39 |
0.60 |
0.86 |
|
|
|
|
|
0.50 |
|
0.70 |
0.810 (1) |
1.140 (1) |
1.570 (1) |
|
|
R-404A |
Nom. |
kW |
|
|
|
|
|
|
|
|
|
|
|
1.280 (1) |
2.030 (1) |
2.670 (1) |
|
|
R-407A |
Nom. |
kW |
|
|
|
0.80 |
0.94 |
1.11 |
|
0.50 |
|
0.66 |
|
1.150 (1) |
1.820 (1) |
2.390 (1) |
|
|
R-407F |
Nom. |
kW |
|
|
|
0.79 |
0.94 |
1.07 |
|
0.49 |
|
0.65 |
|
1.210 (1) |
1.830 (1) |
2.530 (1) |
COP |
Medium temperature |
R-134a |
|
1.50 |
1.77 |
1.86 |
|
|
|
|
|
1.77 |
|
1.85 |
1.57 (1) |
1.81 (1) |
1.91 (1) |
|
|
R-404A |
|
|
|
|
|
|
|
|
|
|
|
1.78 (1) |
1.86 (1) |
1.80 (1) |
|
|
R-407A |
|
|
|
1.66 |
1.78 |
1.74 |
|
1.59 |
|
1.62 |
|
1.77 (1) |
1.85 (1) |
1.80 (1) |
|
|
R-407F |
|
|
|
1.77 |
1.85 |
1.93 |
|
1.77 |
|
1.76 |
|
1.65 (1) |
1.86 (1) |
1.80 (1) |
Paramètres à pleine charge à temp. ext. 32 °C (Point A) |
R-134a |
Te -10 °C |
Puiss. frigorifique nominale (PA) |
kW |
0.59 |
1.06 |
1.60 |
|
|
|
|
|
0.89 |
|
1.28 |
1.27 |
2.06 |
2.99 |
|
|
|
Puissance absorbée nominale (DA) |
kW |
0.39 |
0.60 |
0.86 |
|
|
|
|
|
0.50 |
|
0.70 |
0.81 |
1.14 |
1.57 |
|
|
|
COP nominal (COPA) |
|
1.50 |
1.77 |
1.86 |
|
|
|
|
|
1.77 |
|
1.85 |
1.57 |
1.81 |
1.91 |
|
R-404A |
Te -10 °C |
Puiss. frigorifique nominale (PA) |
kW |
|
|
|
|
|
|
|
|
|
|
|
2.27 |
3.76 |
4.81 |
|
|
|
Puissance absorbée nominale (DA) |
kW |
|
|
|
|
|
|
|
|
|
|
|
1.28 |
2.03 |
2.67 |
|
|
|
COP nominal (COPA) |
|
|
|
|
|
|
|
|
|
|
|
1.78 |
1.86 |
1.80 |
|
R-407A |
Te -10 °C |
Puiss. frigorifique nominale (PA) |
kW |
|
|
|
1.33 |
1.66 |
1.92 |
|
0.80 |
|
1.07 |
|
2.04 |
3.37 |
4.30 |
|
|
|
Puissance absorbée nominale (DA) |
kW |
|
|
|
0.80 |
0.94 |
1.11 |
|
0.50 |
|
0.66 |
|
1.15 |
1.82 |
2.39 |
|
|
|
COP nominal (COPA) |
|
|
|
1.66 |
1.78 |
1.74 |
|
1.59 |
|
1.62 |
|
1.77 |
1.85 |
1.80 |
|
R-407F |
Te -10 °C |
Puiss. frigorifique nominale (PA) |
kW |
|
|
|
1.41 |
1.74 |
2.08 |
|
0.86 |
|
1.15 |
|
1.99 |
3.40 |
4.55 |
|
|
|
Puissance absorbée nominale (DA) |
kW |
|
|
|
0.79 |
0.94 |
1.07 |
|
0.49 |
|
0.65 |
|
1.21 |
1.83 |
2.53 |
|
|
|
COP nominal (COPA) |
|
|
|
1.77 |
1.85 |
1.93 |
|
1.77 |
|
1.76 |
|
1.65 |
1.86 |
1.80 |
Paramètres à pleine charge à temp. ext. 25 °C |
R-134a |
Te -10 °C |
Puiss. frigorifique (P2) |
kW |
0.62 |
1.18 |
1.79 |
|
|
|
|
|
0.97 |
|
1.44 |
1.41 |
2.26 |
3.23 |
|
|
|
Puissance absorbée (D2) |
kW |
0.34 |
0.58 |
0.78 |
|
|
|
|
|
0.48 |
|
0.65 |
0.78 |
1.09 |
1.50 |
|
|
|
COP déclaré (COP2) |
|
1.84 |
2.05 |
2.30 |
|
|
|
|
|
2.01 |
|
2.22 |
1.81 |
2.08 |
2.15 |
|
R-404A |
Te -10 °C |
Puiss. frigorifique (P2) |
kW |
|
|
|
|
|
|
|
|
|
|
|
2.51 |
4.15 |
5.26 |
|
|
|
Puissance absorbée (D2) |
kW |
|
|
|
|
|
|
|
|
|
|
|
1.25 |
1.97 |
2.58 |
|
|
|
COP déclaré (COP2) |
|
|
|
|
|
|
|
|
|
|
|
2.01 |
2.11 |
2.04 |
|
R-407A |
Te -10 °C |
Puiss. frigorifique (P2) |
kW |
|
|
|
1.35 |
1.73 |
1.94 |
|
0.82 |
|
1.09 |
|
2.25 |
3.69 |
4.67 |
|
|
|
Puissance absorbée (D2) |
kW |
|
|
|
0.78 |
0.91 |
1.04 |
|
0.48 |
|
0.65 |
|
1.12 |
1.77 |
2.32 |
|
|
|
COP déclaré (COP2) |
|
|
|
1.74 |
1.90 |
1.87 |
|
1.69 |
|
1.69 |
|
2.00 |
2.09 |
2.01 |
|
R-407F |
Te -10 °C |
Puiss. frigorifique (P2) |
kW |
|
|
|
1.47 |
1.85 |
2.15 |
|
0.89 |
|
1.20 |
|
2.34 |
3.72 |
5.01 |
|
|
|
Puissance absorbée (D2) |
kW |
|
|
|
0.75 |
0.89 |
0.97 |
|
0.46 |
|
0.62 |
|
1.17 |
1.74 |
2.43 |
|
|
|
COP déclaré (COP2) |
|
|
|
1.95 |
2.07 |
2.22 |
|
1.94 |
|
1.94 |
|
2.00 |
2.14 |
2.06 |
Paramètres à pleine charge et temp. ext. 43°C |
R-134a |
Te -10 °C |
Puiss. frigorifique (P3) |
kW |
0.51 |
0.86 |
1.34 |
|
|
|
|
|
0.74 |
|
1.06 |
0.98 |
1.63 |
2.51 |
|
|
|
Puissance absorbée (D3) |
kW |
0.36 |
0.62 |
0.89 |
|
|
|
|
|
0.53 |
|
0.71 |
0.85 |
1.21 |
1.68 |
|
|
|
COP déclaré (COP3) |
|
1.42 |
1.40 |
1.50 |
|
|
|
|
|
1.40 |
|
1.49 |
1.16 |
1.35 |
1.49 |
|
R-404A |
Te -10 °C |
Puiss. frigorifique (P3) |
kW |
|
|
|
|
|
|
|
|
|
|
|
1.78 |
2.97 |
3.86 |
|
|
|
Puissance absorbée (D3) |
kW |
|
|
|
|
|
|
|
|
|
|
|
1.34 |
2.14 |
2.83 |
|
|
|
COP déclaré (COP3) |
|
|
|
|
|
|
|
|
|
|
|
1.33 |
1.39 |
1.36 |
|
R-407A |
Te -10 °C |
Puiss. frigorifique (P3) |
kW |
|
|
|
|
|
1.79 |
|
0.76 |
|
|
|
1.67 |
2.83 |
3.68 |
|
|
|
Puissance absorbée (D3) |
kW |
|
|
|
|
|
1.15 |
|
0.53 |
|
|
|
1.19 |
1.90 |
2.49 |
|
|
|
COP déclaré (COP3) |
|
|
|
|
|
1.56 |
|
1.42 |
|
|
|
1.40 |
1.49 |
1.48 |
|
R-407F |
Te -10 °C |
Puiss. frigorifique (P3) |
kW |
|
|
|
|
|
1.85 |
|
0.79 |
|
|
|
1.74 |
2.86 |
3.89 |
|
|
|
Puissance absorbée (D3) |
kW |
|
|
|
|
|
1.17 |
|
0.54 |
|
|
|
1.27 |
1.98 |
2.70 |
|
|
|
COP déclaré (COP3) |
|
|
|
|
|
1.58 |
|
1.46 |
|
|
|
1.37 |
1.45 |
1.44 |
Casing |
Colour |
|
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Gris clair |
Dimensions |
Unité |
Hauteur |
mm |
606 |
606 |
606 |
606 |
606 |
662 |
662 |
606 |
606 |
606 |
606 |
662 |
662 |
662 |
|
|
Largeur |
mm |
876 |
876 |
876 |
876 |
876 |
1,101 |
1,101 |
876 |
876 |
876 |
876 |
1,101 |
1,101 |
1,101 |
|
|
Profondeur |
mm |
430 |
430 |
430 |
430 |
430 |
444 |
444 |
430 |
430 |
430 |
430 |
444 |
444 |
444 |
Poids |
Unité |
kg |
49 |
57 |
58 |
57 |
58 |
67 |
68 |
49 |
57 |
56 |
58 |
68 |
70 |
72 |
Ventilateur |
Type |
|
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Axial |
Réfrigérant |
Type |
|
R-134a |
R-134a |
R-134a |
|
|
|
|
|
R-134a |
|
R-134a |
R-134a |
R-134a |
R-134a |
|
Type 2 |
|
|
|
R-407A |
R-407A |
R-407A |
|
R-407A |
|
R-407A |
|
R-404A |
R-404A |
R-404A |
|
Type 3 |
|
|
|
R-407F |
R-407F |
R-407F |
|
R-407F |
|
R-407F |
|
R-407A |
R-407A |
R-407A |
|
Type 4 |
|
|
|
|
|
|
|
|
|
|
|
R-407F |
R-407F |
R-407F |
|
Type 5 |
|
|
|
R-448A |
R-448A |
R-448A |
R-448A |
R-448A |
|
R-448A |
|
|
|
|
|
PRP |
|
1,430 |
1,430 |
1,430 |
|
|
|
|
|
1,430 |
|
1,430 |
1,430.0 |
1,430.0 |
1,430.0 |
|
PRP type 2 |
|
|
|
2,107 |
2,107 |
2,107 |
|
2,107 |
|
2,107 |
|
3,921.6 |
3,921.6 |
3,921.6 |
|
PRP type 3 |
|
|
|
1,825 |
1,825 |
1,825 |
|
1,825 |
|
1,825 |
|
2,107.0 |
2,107.0 |
2,107.0 |
|
PRP type 4 |
|
|
|
|
|
|
|
|
|
|
|
1,825.0 |
1,825.0 |
1,825.0 |
|
PRP type 5 |
|
|
|
1,387 |
1,387 |
1,387 |
1,387 |
1,387 |
|
1,387 |
|
|
|
|
Alimentation électrique |
Phase |
|
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
1~ |
|
Fréquence |
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
Tension |
V |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
230 |
Remarques |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - SRG 20°C, Ta=32°C, Te=-35°C |
(1) - Se référer à la condition: Temp. ext. = 32°C, temp. d'évap. = -10°C et surchauffe 10K (applic. temp. moy.) |
(1) - Se référer à la condition: Temp. ext. = 32°C, temp. d'évap. = -10°C et surchauffe 10K (applic. temp. moy.) |
(1) - Se référer à la condition: Temp. ext. = 32°C, temp. d'évap. = -10°C et surchauffe 10K (applic. temp. moy.) |
|
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
(2) - Niv. de press. son. mesurée à 10m en chambre anéchoïque |
|
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
(3) - Son fonctionnement repose sur des gaz à effet de serre fluorés. |
|
|
|
|
|
|
|
|
|
|
|
|
(4) - Contient des gaz à effet de serre fluorés. |
(4) - Contient des gaz à effet de serre fluorés. |
(4) - Contient des gaz à effet de serre fluorés. |